Intrinsically Safe Encoder Transducer type PEI
The intrinsically safe encoder transducer type PEI is designed to energise intrinsically safe incremental encoders and separate the signal from the encoder. The intrinsically safe encoder transducer type PEI is an intrinsically safe device with protection rating of ia, providing galvanic separation between the intrinsically safe encoder and the non-intrinsically safe power and decoding part.
PEI consists of:
- supply system with a high-frequency converter for galvanic separation (4kV) and diode barrier to achieve the protection level of ia,
- three transmission channels with galvanic separation between intrinsically safe and non-intrinsically safe parts.
Characteristics
- energises incremental encoders with intrinsically safe voltage,
- separation of signals from the encoder,
- can be used as an intrinsically safe power supply and a signal separator.
Explosion protection
Marking
I M2 [Ex ia Ma] I
II 2G [Ex ia Ga] IIB T4
Ambient temperature
-20°C to +70°C
Certificate
OBAC 09 ATEX 408U
Rated values
Rated data | |
Enclosure protection degree | IP20 |
Housing dimensions | (450-350) x (188 without keys) x 164 mm |
Weight | 113.6 x 99 x 22.6 |
Supply voltage | 24 or 42 V AC / V DC |
Supply voltage frequency | 50/60 AC Hz or DC |
Ambient temperature | from -20 ° C ° C to 70 ° C ° C ºC |
Coding
P | E | I | – | * | . | * |
where:
1 – OC version (open collector of the transistor), Uo = 12.6V (terminals 15,16)
2 – TTL version (outputs 5V max 1mA), Uo = 12.6V (terminals 15.16)
3 – HTL version (output Up to 30V max 5mA, terminals 1,8), Uo = 12,6V (terminals 15,16)
4 – OC version (open collector of the transistor), Uo = 5.36V (terminals 15.16)
5 – TTL version (outputs 5V max 1mA), Uo = 5.36V (terminals 15.16)
6 – HTL version (output Up to 30V max 5mA, terminals 1.8), Uo = 5.36V (terminals 15.16)
7 – Push-Pull version (output 5, 12, 24V), Uo = 12.6V (terminals 15, 16)
8 – Push-Pull execution (output 5, 12, 24V), Uo = 5.36 (terminals 15, 16)
9 – version Power supply Uo = 12.6V (terminals 15, 16)
10 – version Power supply Uo = 5.36V (terminals 15.16)
1 – version of the supply voltage 24V DC
2 – 42V AC power supply version
Other parameters, including intrinsically safe ones, are included in the instruction manual available on the manufacturer’s website.